This post has been de-listed
It is no longer included in search results and normal feeds (front page, hot posts, subreddit posts, etc). It remains visible only via the author's post history.
So we were at this house for a no cool, everything is running fine, no electrical problems, and then I throw the gauges on i had it at 110/295-310 psi and 89° on liquid line and my lead says let's add gas since there was no visual sign of a leak so I grab the jug of 410 and start weighing it in. 3lbs later were at 135/320 and it got to 96° on liquid line. We started with a subcool from between 11° and 9° and ended with between 4° and 6°. Now I'm just a helper so forgive my ignorance here, but shouldn't that not happen when adding gas?
Subreddit
Post Details
- Posted
- 5 years ago
- Reddit URL
- View post on reddit.com
- External URL
- reddit.com/r/HVAC/commen...