This post has been de-listed
It is no longer included in search results and normal feeds (front page, hot posts, subreddit posts, etc). It remains visible only via the author's post history.
3
Galvanic corrosion concern with zinc plated pipe fittings in a cast iron pump?
Post Flair (click to view more posts with a particular flair)
Post Body
The pump has a cast iron housing and impeller, and the pipes are going to be copper. I bought some dielectric unions, but the "iron" side is zinc plated. My gut is telling me it's ok since it's only a coating, and therefore will only corrode until the coating is gone, but this galvanic corrosion chart has me unsure. It's an open system, outside, and the water will be pretty conductive. Thoughts?
Author
Account Strength
90%
Account Age
6 years
Verified Email
Yes
Verified Flair
No
Total Karma
3,441
Link Karma
704
Comment Karma
2,705
Profile updated: 1 day ago
Subreddit
Post Details
We try to extract some basic information from the post title. This is not
always successful or accurate, please use your best judgement and compare
these values to the post title and body for confirmation.
- Posted
- 7 months ago
- Reddit URL
- View post on reddit.com
- External URL